Check Shot

The Check Shot option opens the 12d Field - Check Shot panel. This panel is used to check the integrity of the current station setup by taking a measurement to a known point. Continue down the page to see the 12d Field - Check Shot panel options. To view the 12d Field - Instrument Setup panel, Use: Show Options [...]
Read More

Checks (Setout)

The Checks menu panel is used to display options for conducting survey checks with the instrument in the field. Continue down the page to see the various menu panel options. To view the Checks (Setout) menu panel, Use: Show Options => Checks The Checks (Setout) menu panel consists of the below options: Check Shot - [...]
Read More

Station LSA

The Station LSA option opens the 12d Field – Least Squares Resection panel. This panel is used to calculate and establish the position of the instrument in relation to known control points using the mathematical reduction known as least squares, this method is known as a least squares resection. Continue down the page to see the 12d Field [...]
Read More

Station Height Cal

The Station Height Cal option opens the 12d Field - Inst Stat Hgt Cal panel. This panel is used to establish the level of the instrument station point. Note: The 12d Field - Inst Stat Hgt Cal panel is ONLY used for establishing level and therefore will use the positional co-ordinates of the last known setup. This option [...]
Read More

Station Helmert

The Station Helmert option opens the 12d Field – Helmert Resection panel. This panel is used to calculate and establish the position of the instrument in relation to known control points, this method is known as a resection. Continue down the page to see the 12d Field – Helmert Resection panel options. To view the 12d Field – Helmert Resection panel, [...]
Read More

Common Function Panel Buttons

In 12d Field there are several buttons that are common and have the same function across many 12d Field panels. Scroll down the page to see the functions of these buttons. MEASUREMENT STYLES Distance SNGL –  The <Distance SNGL> button when pressed, will take a single bearing and distance shot. Distance MULT – The <Distance MULT> button when pressed, will take [...]
Read More

Station Standard

The Station Standard option opens the 12d Field - Instrument Setup panel. This panel is used to establish the position of the instrument over a station point. Continue down the page to see the 12d Field - Instrument Setup panel options. To view the 12d Field - Instrument Setup panel, Use: Show Options => Station Setup => Station [...]
Read More

Station Details

The Station details are displayed in the 12d Field - Current Setup Details panel. Scroll down the page to see the various information that the 12d Field - Current Setup Details panel displays. To view the 12d Field - Current Setup Details panel, Use: Show Options => Station Setup => Station Details See the below image of [...]
Read More

Station Setup

The Station Setup menu panel is used to display current station setup information and to set up a new station. Continue down the page to see the various menu panel options. To view the Station Setup menu panel, Use: Show Options => Station Setup The Station Setup menu panel consists of the below options: Station Details [...]
Read More

Show Options

The second button from the right of the 12d Field Control Bar, when pressed, opens the 12d Field Options menu panel. The list of options in the Options menu are: Station Setup - When pressed opens up the Station Setup menu panel Checks - When pressed opens up the checks (Setout) menu panel Setout - When pressed opens up the [...]
Read More